COPIER > OPTION > CLEANING
CLN-ADJ
Set black band length for cleaning
Lv.1 Details
To set black band length for cleaning.
When setting CLN-SW to 2 and setting CLN-ADJ to 0, the setting
value "7" of environment control for each process speed is executed.
When setting CLN-SW to 2 and setting CLN-ADJ to other than 0,
operation is accorded with the setting value of CLN-ADJ.
When setting CLN-SW to 0, operation is not executed regardless of
the CLN-ADJ setting.
However, with imageRUNNER ADVANCE 8105/8095/8085 (Pro),
black band sequence is not executed although the setting value of
environment control is "7". Set CLN-ADJ to other than 0 to execute
the operation.
Use case
When amount of toner supply to the Cleaning Blade is decreased
extremely
Adj/set/operate method Enter the setting value, and then press OK key.
Display/adj/set range
0 to 4
0: Based on environment control, 1: 1000 mm, 2: 2098 mm, 3: 3548
mm, 4: 5000 mm
Default value
0
Related service mode
COPIER> OPTION> CLEANING> CLN-SW
8
Service Mode > COPIER > OPTION > ENV-SET
T-8-64
8
Service Mode > COPIER > OPTION > ENV-SET
ENV-SET
COPIER > OPTION > ENV-SET
ENVP-INT
Temp, humid/Fix Roll temp log get cycle
Lv.1 Details
To set the cycle to obtain log of the temperature and humidity inside
the machine or the surface temperature of the Fixing Roller.
As the value is incremented by 1, the cycle is increased by 1 minute.
Obtained log can be displayed by selecting the following: COPIER >
DISPLAY > ENVRNT
Use case
At trouble analysis
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
Display/adj/set range
0 to 480
Unit
1 minute
Default value
60
Related service mode
COPIER> DISPLAY> ENVRNT
DRY-CISU
ON/OFF of condensation prevention mode
Lv.1 Details
To set ON/OFF of condensation mode.
When droplets are appeared on the Scanner Unit due to
condensation and image failure or E225 occurs, set "1: ON".
By selecting 1, the Scanner Unit (paper front) stops the fan for
15 seconds and the Scanner Unit (paper back) lights LED for 30
seconds from the next startup.
Use case
When droplets are appeared on the Scanner Unit due to
condensation and image failure or E225 occurs
Display/adj/set range
0 to 1
0: OFF (Normal mode), 1: ON (Anti-condensation mode)