Canon imageRUNNER ADVANCE 8105 Series Service Manual page 860

Hide thumbs Also See for imageRUNNER ADVANCE 8105 Series:
Table of Contents

Advertisement

COPIER > OPTION > IMG-DEV
TBLTBIS+
Setting of ETB cleaning bias (+)
Lv.1 Details
To set the transfer current value to apply cleaning bias (+) at the time
of ETB cleaning.
As the value is increased, the soiling of the back side of paper is
decreased, but the life of the ETB is shortened.
Compared with TBLTCLSW, productivity can be sustained, but the
life of the ETB is shortened further.
Use case
When the back side of paper is soiled
Adj/set/operate method Enter the setting value, and then press OK key.
Caution
As the greater value is set, the life of the ETB is shortened.
Display/adj/set range
-10 to 10
Unit
10 micro A
Default value
0 (100 micro A)
Related service mode
COPIER> OPTION> IMG-DEV> TBLTCLSW, TBLTBIS-, TBLTTMS
TBLTBIS-
Setting of ETB cleaning bias (-)
Lv.1 Details
To set the transfer current value to apply cleaning bias (-) at the time
of ETB cleaning.
Use case
When the back side of paper is soiled
Adj/set/operate method Enter the setting value, and then press OK key.
Caution
Do not use this at the normal service.
Display/adj/set range
0 to 5
Unit
10 micro A
Default value
0 (-50 micro A)
Related service mode
COPIER> OPTION> IMG-DEV> TBLTCLSW, TBLTBIS+, TBLTTMS
TBLTTMS
Set ETB cleaning bias application times
Lv.1 Details
To set the number of times to apply cleaning bias at the time of ETB
cleaning.
Apply positive (+) and negative (-) cleaning bias alternately.
As the value is increased, the soiling of the back side of paper is
decreased, but the life of the ETB is shortened and productivity is
decreased.
Use case
When the back side of paper is soiled
Adj/set/operate method Enter the setting value, and then press OK key.
Caution
As the greater value is set, the life of the ETB is shortened and
productivity is decreased.
Display/adj/set range
1 to 10
Unit
Number of times
Default value
2
Related service mode
COPIER> OPTION> IMG-DEV> TBLTCLSW, TBLTBIS+, TBLTBIS-
8
Service Mode > COPIER > OPTION > IMG-DEV
8
Service Mode > COPIER > OPTION > IMG-DEV
COPIER > OPTION > IMG-DEV
Set first idle rotn time in HH Ev
DRM-IDL3
To set the idle rotation time to be performed first time for the day in
Lv.1 Details
an HH (high temperature and high humidity) environment.
When image density for the first time of the day is low
Use case
Adj/set/operate method Enter the setting value, and then press OK key.
Display/adj/set range
0 to 20 (0: OFF)
Unit
30 seconds
Default value
1 (60 seconds)
Related service mode
COPIER> OPTION> IMG-DEV> DRM-IDL, DRM-IDL2
8-145
T-8-60
8-145

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents