4
Parts Replacement and Clearning > Pickup/Feed System > Removing the Registration Unit
1-3)
Push to release the Release Springs at both sides of the Rail, and then further pull
out the Fixing Feed Unit until it stops.
4
Parts Replacement and Clearning > Pickup/Feed System > Removing the Registration Unit
<Procedure>
1) Remove the Fixing Feed Right Front Upper Cover
•
1 Screw
2) Lift the ETB Unit in the direction of the arrow.
F-4-452
4-222
F-4-453
F-4-454
4-222