Canon imageRUNNER ADVANCE 8105 Series Service Manual page 917

Hide thumbs Also See for imageRUNNER ADVANCE 8105 Series:
Table of Contents

Advertisement

COPIER > COUNTER > DRBL-1
SP-CLAW
Drum Cleaner Separation Claw prts cntr
Lv.1 Details
1st line: Total counter value from the previous replacement
2nd line: Estimated life
Use case
When checking the consumption level of parts/replacing the parts
Adj/set/operate method To clear the counter value: Select the item, and then press Clear key.
To change the estimated life: Select the item, enter the value, and
then press OK key.
Caution
Clear the counter value after replacement.
Display/adj/set range
0 to 99999999
Default value
0
BS-SL-F
Drum Cleaner Side Seal (Front) prts cntr
Lv.1 Details
1st line: Total counter value from the previous replacement
2nd line: Estimated life
Use case
When checking the consumption level of parts/replacing the parts
Adj/set/operate method To clear the counter value: Select the item, and then press Clear key.
To change the estimated life: Select the item, enter the value, and
then press OK key.
Caution
Clear the counter value after replacement.
Display/adj/set range
0 to 99999999
Default value
0
BS-SL-R
Drum Cleaner Side Seal (Rear) prts cntr
Lv.1 Details
1st line: Total counter value from the previous replacement
2nd line: Estimated life
Use case
When checking the consumption level of parts/replacing the parts
Adj/set/operate method To clear the counter value: Select the item, and then press Clear key.
To change the estimated life: Select the item, enter the value, and
then press OK key.
Caution
Clear the counter value after replacement.
Display/adj/set range
0 to 99999999
Default value
0
DVG-CYL
Developing Cylinder parts counter
Lv.1 Details
1st line: Total counter value from the previous replacement
2nd line: Estimated life
Use case
When checking the consumption level of parts/replacing the parts
Adj/set/operate method To clear the counter value: Select the item, and then press Clear key.
To change the estimated life: Select the item, enter the value, and
then press OK key.
Caution
Clear the counter value after replacement.
Display/adj/set range
0 to 99999999
Default value
0
8
Service Mode > COPIER > COUNTER > DRBL-1
8
Service Mode > COPIER > COUNTER > DRBL-1
COPIER > COUNTER > DRBL-1
C1-PU-RL
Right Deck Pickup Roller parts counter
Lv.1 Details
1st line: Total counter value from the previous replacement
2nd line: Estimated life
Use case
When checking the consumption level of parts/replacing the parts
Adj/set/operate method To clear the counter value: Select the item, and then press Clear key.
To change the estimated life: Select the item, enter the value, and
then press OK key.
Caution
Clear the counter value after replacement.
Display/adj/set range
0 to 99999999
Default value
0
C1-SP-RL
Right Deck Separation Roller parts cntr
Lv.1 Details
1st line: Total counter value from the previous replacement
2nd line: Estimated life
Use case
When checking the consumption level of parts/replacing the parts
Adj/set/operate method To clear the counter value: Select the item, and then press Clear key.
To change the estimated life: Select the item, enter the value, and
then press OK key.
Caution
Clear the counter value after replacement.
Display/adj/set range
0 to 99999999
Default value
0
C1-FD-RL
Right Deck Feed Roller parts counter
Lv.1 Details
1st line: Total counter value from the previous replacement
2nd line: Estimated life
Use case
When checking the consumption level of parts/replacing the parts
Adj/set/operate method To clear the counter value: Select the item, and then press Clear key.
To change the estimated life: Select the item, enter the value, and
then press OK key.
Caution
Clear the counter value after replacement.
Display/adj/set range
0 to 99999999
Default value
0
C2-PU-RL
Left Deck Pickup Roller parts counter
Lv.1 Details
1st line: Total counter value from the previous replacement
2nd line: Estimated life
Use case
When checking the consumption level of parts/replacing the parts
Adj/set/operate method To clear the counter value: Select the item, and then press Clear key.
To change the estimated life: Select the item, enter the value, and
then press OK key.
Caution
Clear the counter value after replacement.
Display/adj/set range
0 to 99999999
Default value
0