COPIER > OPTION > DSPLY-SW
UI-HOLD
Display/hide of hold job screen
Lv.2 Details
To set whether to display the hold job screen on the Control Panel.
Use case
Upon user's request
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
Display/adj/set range
0 to 1
0: Hide, 1: Display
Default value
1
OPEMANT
ON/OFF of operator maintenance mode
Lv.2 Details
To set ON/OFF of operator maintenance mode.
When setting to ON, "Operator Maintenance Mode" is displayed on
the Settings/Registration screen.
Use case
When starting operator maintenance
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
Display/adj/set range
0 to 1
0: OFF, 1: ON
Default value
0
Related user mode
Settings/Registration > Operator Maintenance Mode
OPLOG-SW
Dis/hide of error log in operator mntc
Lv.2 Details
To set whether to display or hide error/jam/alarm-2 log in operator
maintenance mode.
Use case
Upon user's request
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
Display/adj/set range
0 to 1
0: Hide, 1: Display
Default value
0
OP-ALMT
Set warning mssg timing in operator mntc
Lv.2 Details
To set the timing to display warning message of parts replacement/
cleaning counter in operator maintenance mode.
With this setting, warning message is displayed once before reaching
the specified life of parts or number of sheets for cleaning.
Use case
Upon user's request
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
Display/adj/set range
0 to 1
0: At 100%, 1: At 90% and 100%
Default value
0
8
Service Mode > COPIER > OPTION > DSPLY-SW
8
Service Mode > COPIER > OPTION > DSPLY-SW
COPIER > OPTION > DSPLY-SW
RMT-CNSL
ON/OFF of MEAP console screen
Lv.1 Details
Selecting "1: ON" enables to obtain log for Function Composer on
console screen.
Use case
When obtaining log for Function Composer
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
Display/adj/set range
0 to 1
0: OFF, 1: ON
Default value
0
UI-SBOX
ON/OFF of Advanced Box screen display
Lv.2 Details
To set ON/OFF of the Advanced Box screen on the Control Panel.
Use case
When not displaying the Advanced Box screen on the Control Panel
Display/adj/set range
0 to 1
0: OFF, 1: ON
Default value
Europe: 0, Other than Europe: 1
UI-MEM
ON/OFF of memory media screen display
Lv.2 Details
To set ON/OFF of the memory media screen display on the Control
Panel.
Use case
When not displaying the memory media screen on the Control Panel
Display/adj/set range
0 to 1
0: OFF, 1: ON
Default value
0
UI-NAVI
Dis/hide of introduce to useful features
Lv.2 Details
To set whether to display or hide "Introduction to Useful Features" in
the main menu.
Use case
Upon user's request
Display/adj/set range
0 to 1
0: Hide, 1: Display
Default value
1
UI-MOBP
Display/hide of mobile print
Lv.2 Details
To set whether to display or hide "Mobile Print" in the main menu.
Use case
Upon user's request
Display/adj/set range
0 to 1
0: Hide, 1: Display
Default value
1