DENS

COPIER > DISPLAY > DENS
DMAX-STS
Display of D-max control execution state
Lv.1 Details
To display the D-max control execution state.
Use case
- At periodical maintenance
- When a density failure occurs
- When an alarm or error occurs
Adj/set/operate method N/A (Display only)
Display/adj/set range
0 to 2
0: During execution
1: D-max control is not reflected due to failure in Patch Sensor output
value. (Only potential control is executed.)
2: Not executed (D-max control is OFF with DMAX-SW, DMAXS-
SW).
Appropriate target value 0
Default value
0
Related service mode
COPIER> OPTION> IMG-MCON> DMAX-SW
COPIER> OPTION> IMG-DEV> DMAXS-SW
DMAX-N
Dis of uncoated paper group dev contrast
Lv.1 Details
To display the developing contrast Vcont determined by D-max
control for uncoated paper group.
This value is reflected to VCONT-N, but when the offset adjustment
is performed with DUPDWN-N, this value becomes different.
Use case
When any error occurs on the maximum density or gradation, identify
the cause with this mode.
Adj/set/operate method N/A (Display only)
Display/adj/set range
50 to 300
Unit
V
Appropriate target value 90 to 248
Related service mode
COPIER> OPTION> IMG-DEV> DUPDWN-N
COPIER> DISPLAY> DPOT> VCONT-N
Supplement/memo
Uncoated paper group: uncoated paper/recycled paper/textured
paper/label/postcard/cotton
8
Service Mode > COPIER > DISPLAY > DENS
8
Service Mode > COPIER > DISPLAY > DENS
COPIER > DISPLAY > DENS
DMAX-N-L
Uncoat ppr D-max ctrl Vcont, dens/tgt VL
Lv.2 Details
To display the list of uncoated paper group's D-max control Vcont,
patch detection density and target density value at the latest.
This list consists of maximum Vcont during D-max control and patch
detection density (DENS) 1 to 5.
Use case
When any error occurs on the maximum density or gradation, identify
the cause with this mode. Characteristics of V-D (Vcont and density)
can be grasped, and it is easily identified as high voltage error, laser
error, etc.
Adj/set/operate method N/A (Display only)
Display/adj/set range
Vcont: 50 to 300
Patch detection density: 0 to 1023
Unit
Vcont: V
Patch detection density: None
Appropriate target value Vcont: 150 to 250
Patch detection density: 500 to 1023
Related service mode
COPIER> DISPLAY> DENS> DMAX-N
Supplement/memo
Uncoated paper group: uncoated paper/recycled paper/textured
paper/label/postcard/cotton
P-LED
Patch sensor LED light correction result
Lv.2 Details
Displaying the LED light intensity correction result (DA value) of the
patch sensor
The correction result is used for D-max control or D-half control.
Use case
To separate the cause in the case of failure in maximum density or
gradation.
Adj/set/operate method N/A (display only)
Display/adjust/set range 0 to 255
Appropriate target value 35 to 96
Related service mode
COPIER> FUNCTION> MISC-P> P-LED
P-B-AVE
ETB background dtct result average VL
Lv.2 Details
To display the average value of ETB background detection result by
Patch Sensor.
Detection result is used for D-max control and D-half control.
Use case
When any error occurs on the maximum density or gradation, identify
the cause with this mode.
Adj/set/operate method N/A (Display only)
Display/adj/set range
0 to 1023
Appropriate target value 650 to 850
Related service mode
COPIER> DISPLAY> DENS> P-B-MAX, P-B-MIN