As the value is larger, the density becomes lighter. As the value is smaller, the density
becomes darker.
Enter the adjustment value in a unit of +/- 30 gradually, output the test pattern and make
adjustment while checking the test pattern. If the value is changed dramatically, the image
error (while line) may occur.
5-3) After the adjustment, output a test print and check the image.
When uneven density is seen: Go to 5-4).
When uneven density is not seen: Procedure is ended.
6
Troubleshooting > Image Faults > Uneven density correction by 2D shading
Not Use
F-6-11
F-6-11
Troubleshooting > Image Faults > Uneven density correction by 2D shading
5-4) Adjust the target vertical scanning direction (1 to 27) which uneven density is seen.
After selecting "S-LINE1 to 4", select the target vertical scanning window (1 to 27),
and enter the numerical value using "numerical keypad".
COPIER>FUNCTION>2D-SHADE>S-LINE1 (Level 2) Vertical scanning direction 1 to
8
COPIER>FUNCTION>2D-SHADE>S-LINE2 (Level 2) Vertical scanning direction 9 to
16
COPIER>FUNCTION>2D-SHADE>S-LINE3 (Level 2) Vertical scanning direction 17 to
24
COPIER>FUNCTION>2D-SHADE>S-LINE4 (Level 2) Vertical scanning direction 25 to
32
MEMO:
Be sure to switch the screen after entering the value. Unless the screen is switched, the
numerical value is not reflected. (Actually, the value is not reflected on the screen, but it
is retained internally.)
When the vertical scanning direction (25 and 26 lines) is adjusted, the adjustment value
of the horizontal scanning direction (A to P) is also changed.
As the value is larger, the density becomes lighter. As the value is smaller, the density
becomes darker.
Enter the adjustment value in a unit of +/- 30 gradually, output the test pattern and
make adjustment while checking the test pattern. If the value is changed dramatically,
the image error (while line) may occur.
5-5) After the adjustment, output a test print and check the image to complete the
procedure.
6-9
6-9