Alarm
Title
Code
30-0004
Pre-transfer Charging
Movement: Pre-transfer charging high voltage is not output. An
PCB Harness
disconnection
Cause: Connection error of the Pre-transfer Charging PCB
(connection error)
(PCB26).
Measures:
1. Check the connection between the Main Driver PCB (PCB2)
and the High Voltage Unit.
Main Driver PCB side: J112, High Voltage Unit side: J3098
2. Check the connection inside of the High Voltage Unit.
High Voltage Unit inlet side: J3098, Pre-transfer Charging
PCB side: J3544
3. Replace the Pre-transfer Charging PCB (PCB26).
4. Replace the Main Driver PCB (PCB2).
31-0005
Environment Sensor
Movement: It becomes as follow: environment temperature= 0
reading alarm
Cause: Connection of the Environment Sensor cannot be
detected.
Measures:
1. Check the connection of the Environment Sensor (THU1).
2. Replace the Environment Sensor (THU1).
7
Error Code > Alarm Code > List of Alarm Code
A. movement /B. cause /C. measures
image error like discharge trace occurs.
degC, environment humidity= 0%.
7
Error Code > Alarm Code > List of Alarm Code
Alarm
Title
Code
Movement: Not reflecting the result of VL control. To the laser
32-0002
Potential control (VL
control) error
Cause: The measured value in the dark area (VL) differs over
+/-10V but less than +/-30V than the target potential at
potential control.
Measures: If there is no influence on image, measures are not
1. Check the installation of the Pre-exposure LED (connector
connection, open circuit, the caught cable).
2. Check the installation of the Primary Charging Assembly
(connector connection, open circuit, the caught cable).
3. Check the fixation state of the Drum and the Drum Shaft
(check if the drum fixation cylinder is properly installed).
4. Check if the Dustproof Glass is soiled. If necessary, clean it.
5. Check the installation of the Laser Scanner Unit (connector
connection, open circuit, the caught cable).
6. Check the installation and connection of the Primary
Charging High Voltage PCB (PCB11) (connector connection,
open circuit, the caught cable).
7. Check the installation of the Potential Sensor (connector
connection, open circuit, the caught cable).
8. Check the installation and connection of the Drum Motor (M1)
(connector connection, open circuit, the caught cable).
9. Replace the parts.
Primary Charging Assembly
Laser Scanner Unit
Potential Sensor
Primary Charging High Voltage PCB (PCB11)
Drum Motor (M1)
Main Driver PCB (PCB2)
DC Controller PCB (PCB1)
33-0001
Delivery Assembly
Movement: No change.
Decurler Fan alarm
Cause: Connector disconnection of the Paper Cooling Fan
(FM5).
Failure of the Paper Cooling Fan (FM5).
Measures: Check the connector -> Replace the Paper Cooling
33-0002
Feed Fan alarm
Movement: No change.
Cause: Connector disconnection of the Registration Motor/
Duplex Motor Cooling Fan (FM42).
Failure of the Registration Motor/Duplex Motor Cooling
Fan (FM42).
Measures: Check the connector -> Replace the Registration
A. movement /B. cause /C. measures
power determined with VL control, the power with
which the previous potential control was succeeded
(within target potential +/-10V) is applied.
needed. If not, execute the following measures.
Fan (FM5).
Motor/Duplex Motor Cooling Fan (FM42).
7-98