CCD

COPIER > DISPLAY > CCD
TARGET-B
Shading target value (B)
Lv.2 Details
To display the shading target value of Blue.
Continuous display of 0 (minimum) or FFFF (maximum) is considered
a failure of the Reader Controller PCB.
Use case
- When replacing the Reader Controller PCB
- At scanned image failure
Adj/set/operate method N/A (Display only)
Display/adj/set range
0 to FFFF
Appropriate target value 512 to 2047
TARGET-G
Shading target value (G)
Lv.2 Details
To display the target value of Green.
Continuous display of 0 (minimum) or FFFF (maximum) is considered
a failure of the Reader Controller PCB.
Use case
- When replacing the Reader Controller PCB
- At scanned image failure
Adj/set/operate method N/A (Display only)
Display/adj/set range
0 to FFFF
Appropriate target value 512 to 2047
TARGET-R
Shading target value (R)
Lv.2 Details
To display the shading target value of Red.
Continuous display of 0 (minimum) or FFFF (maximum) is considered
a failure of the Reader Controller PCB.
Use case
- When replacing the Reader Controller PCB
- At scanned image failure
Adj/set/operate method N/A (Display only)
Display/adj/set range
0 to FFFF
Appropriate target value 512 to 2047
GAIN-OB
Gain level of Img Sensor odd bit(B): frt
Lv.2 Details
To display the Blue gain level adjustment value in odd-numbered bit
on CMOS Sensor of Scanner Unit (paper front).
Continuous display of upper limit is considered a failure of the
Scanner Unit/Reader Controller PCB.
Use case
- When replacing the Reader Controller PCB
- At scanned image failure
Adj/set/operate method N/A (Display only)
Display/adj/set range
0 to 48
GAIN-OG
Gain level of Img Sensor odd bit(G): frt
Lv.2 Details
To display the Green gain level adjustment value in odd-numbered
bit on CMOS Sensor of Scanner Unit (paper front).
Continuous display of upper limit is considered a failure of the
Scanner Unit/Reader Controller PCB.
Use case
- When replacing the Reader Controller PCB
- At scanned image failure
Adj/set/operate method N/A (Display only)
Display/adj/set range
0 to 48
8
Service Mode > COPIER > DISPLAY > CCD
8
Service Mode > COPIER > DISPLAY > CCD
COPIER > DISPLAY > CCD
GAIN-OR
Gain level of Img Sensor odd bit(R): frt
Lv.2 Details
To display the Red gain level adjustment value in odd-numbered bit
on CMOS Sensor of Scanner Unit (paper front).
Continuous display of upper limit is considered a failure of the
Scanner Unit/Reader Controller PCB.
Use case
- When replacing the Reader Controller PCB
- At scanned image failure
Adj/set/operate method N/A (Display only)
Display/adj/set range
0 to 48
GAIN-EB
Gain level of Img Sensor even bit(B):frt
Lv.2 Details
To display the Blue gain level adjustment value in even-numbered bit
on CMOS Sensor of Scanner Unit (paper front).
Continuous display of upper limit is considered a failure of the
Scanner Unit/Reader Controller PCB.
Use case
- When replacing the Reader Controller PCB
- At scanned image failure
Adj/set/operate method N/A (Display only)
Display/adj/set range
0 to 48
GAIN-EG
Gain level of Img Sensor even bit(G):frt
Lv.2 Details
To display the Green gain level adjustment value in even-numbered
bit on CMOS Sensor of Scanner Unit (paper front).
Continuous display of upper limit is considered a failure of the
Scanner Unit/Reader Controller PCB.
Use case
- When replacing the Reader Controller PCB
- At scanned image failure
Adj/set/operate method N/A (Display only)
Display/adj/set range
0 to 48
GAIN-ER
Gain level of Img Sensor even bit(R):frt
Lv.2 Details
To display the Red gain level adjustment value in even-numbered bit
on CMOS Sensor of Scanner Unit (paper front).
Continuous display of upper limit is considered a failure of the
Scanner Unit/Reader Controller PCB.
Use case
- When replacing the Reader Controller PCB
- At scanned image failure
Adj/set/operate method N/A (Display only)
Display/adj/set range
0 to 48
LAMP-BW
Scan Lamp intensity adj VL(B&W): front
Lv.2 Details
To display the LED light intensity adjustment value of Scanner Unit
(paper front) in B&W scanning mode.
Use case
When image failure occurs at front side scanning in B&W mode
Adj/set/operate method N/A (Display only)
Display/adj/set range
0 to 164
Appropriate target value 20 to 163
Supplement/memo
LED cannot be replaced individually. Replace the Scanner Unit.