COPIER > FUNCTION > INSTALL
COM-TEST
Disp connect result w/ Sales Co's server
Lv.1 Details
To display the result of the connection test with the sales company's
server.
Use case
When using Embedded-RDS
Adj/set/operate method Select the item, and then press OK key.
Caution
Be sure to use E-RDS, RGW-PORT, COM-TEST, COM-LOG and
RGW-ADR as a set.
Display/adj/set range
During operation: ACTIVE, When connection is completed: OK,
When connection is failed: NG
Related service mode
COPIER> FUNCTION> INSTALL> E-RDS, RGW-PORT, COM-LOG,
RGW-ADR
Supplement/memo
Embedded-RDS: Function to send device information such as the
device counter, failure, and consumables to the sales company's
server via SOAP protocol
COM-LOG
Disp connect error w/ Sales Co's server
Lv.1 Details
To display error information when the connection with the sales
company's server failed.
Use case
When using Embedded-RDS
Adj/set/operate method Display only
Caution
Be sure to use E-RDS, RGW-PORT, COM-TEST, COM-LOG and
RGW-ADR as a set.
Display/adj/set range
Year, date, time, error code, error detail information (maximum 128
characters)
Related service mode
COPIER> FUNCTION> INSTALL> E-RDS, RGW-PORT, COM-TEST,
RGW-ADR
Supplement/memo
Embedded-RDS: Function to send device information such as the
device counter, failure, and consumables to the sales company's
server via SOAP protocol
RGW-ADR
URL setting of Sales Company's server
Lv.1 Details
To set the URL of the sales company's server to be used for
Embedded-RDS.
Use case
When using Embedded-RDS
Adj/set/operate method 1) Select the URL.
2) Enter the URL, and then press OK key.
2) Turn OFF/ON the main power switch.
Caution
- Do not use Shift-JIS character strings.
- Be sure to use E-RDS, RGW-PORT, COM-TEST, COM-LOG and
RGW-ADR as a set.
Display/adj/set range
URL
Default value
https://a01.ugwdevice.net/ugw/agentif010
Related service mode
COPIER> FUNCTION> INSTALL> E-RDS, RGW-PORT, COM-TEST,
COM-LOG
Supplement/memo
Embedded-RDS: Function to send device information such as the
device counter, failure, and consumables to the sales company's
server via SOAP protocol
8
Service Mode > COPIER > FUNCTION > INSTALL
8
Service Mode > COPIER > FUNCTION > INSTALL
COPIER > FUNCTION > INSTALL
CNT-DATE
Set counter send start date to SC server
Lv.1 Details
To set the year, month, date, hour and minute to send counter
information to the sales company's server.
This is displayed only when the Embedded-RDS third-party extended
function is available.
Use case
When the Embedded-RDS third-party expanded function is available
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
Display/adj/set range
YYYYMMDDHHMM (12 digits)
YYYY: Year, MM: Month, DD: Date, HH: Hour, MM: Minute
Default value
000000000000
Supplement/memo
Embedded-RDS: Function to send device information such as the
device counter, failure, and consumables to the sales company's
server via SOAP protocol
CNT-INTV
Set counter send interval to SC server
Lv.1 Details
To set the interval of sending counter information to the sales
company's server in a unit of one hour.
This is displayed only when the Embedded-RDS third-party extended
function is available.
Use case
- When restarting potential control after execution of COPIER>
OPTION> IMG-FIX> PO-CNT
- When the D-max control condition is changed
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
Display/adj/set range
1 to 168 (=1 week)
Unit
1 hour
Default value
24
Supplement/memo
Embedded-RDS: Function to send device information such as the
device counter, failure, and consumables to the sales company's
server via SOAP protocol
8-111
8-111