Setting for Mirroring
1) Specify the setting for mirroring.
Service Mode > COPIER > OPTION > FNC-SW > W/RAID; select "1" for W/RAID.
2) Turn OFF/ON the main power switch to enable the setting value.
3) Check that the UI screen is started normally.
4) Open the HDD Cover, and check that the LED is flashing.
The green LED of HDD1 (Slot1) is flashing.
The green and red LEDs of HDD2 (Slot2) are flashing.
CAUTION:
Re-building process starts after setting W/RAID to "1".
When the error indicating the message of "Need to replace Hard Disk (Contact with
Service Technician)" on the UI occurs, re-execute the re-building process as follows;
1) Check the lighted Red LED is for the HDD2.
2) Set Service mode > COPIER > OPTION > FNC-SW > W/RAID to "0".
3) Turn OFF/ON the main power switch of the host machine to enable the setting value.
4) Set Service mode > COPIER > OPTION > FNC-SW > W/RAID to "1".
5) Turn OFF/ON e the main power switch of the host machine to enable the setting
value.
The abovementioned procedure is limited only for the re-building process at the initial
installation. The error occurred at re-building process during operation is not targeted.
9
Installation > [TYPE-4] Option HDD (80GB) + HDD Mirroring Kit or HDD Data Encryption & Mirroring Kit > After Installing HDD Data Encryption &
After Installing HDD Data Encryption & Mirroring Kit
Reporting to the System Administrator at the End of the Work
When you have completed all installation work, report to the system administrator for the
following:
At the point when installation is completed, make explanations about how to check that
the appropriate security function has been added and enabled so that, when the function
becomes uncontrolled, the system administrator can immediately detect the problem and
request <Servicing work when a failure occurs>.
Execution of Auto Gradation Adjustment
When this product is installed, the machine initializes its HDD, resetting the data used for
auto gradation adjustment.
Therefore be sure to execute auto gradation adjustment (full adjust) after installing this kit.
F-9-341
9
Installation > [TYPE-4] Option HDD (80GB) + HDD Mirroring Kit or HDD Data Encryption & Mirroring Kit > After Installing HDD Data Encryption &
9-158
9-158