Parts Replacement and Clearning > Image Formation System > Replacing the Primary Charging Assembly Grid Wire
13) Remove the Shield Plate (Left) and pinch the Grid Wire from the left side to clean it on the
left side with lint-free paper moistened with water.
CAUTION:
The frame of the Primary Charging Assembly may be distorted, so be careful not to
remove both Left and Right Shield Plates simultaneously.
14) Shift the Primary Charging Wire Cleaners (Left and Right).
15) Tighten the 2 screws.
Primary Charging
Wire Cleaners (Left )
4
Parts Replacement and Clearning > Image Formation System > Replacing the Primary Charging Assembly Grid Wire
F-4-105
Primary Charging
Wire Cleaners (Right)
Screws
F-4-106
CAUTION:
Be sure to move the Primary Charging Wire Cleaners (Left and Right) until they stop
and tighten the screws.
Screws
Primary Charging
Primary Charging
Wire Cleaners (Left )
Wire Cleaners (Right)
16) Install the Primary Charging Shutter Unit.(Refer to page 4-143)
4-102
F-4-107
4-102