5) Remove the Fan Duct.
2 Screws
Duct
6) Rotate the Disengage Gear about 90 degrees counterclockwise by hand and lower the ITB
Unit.
CAUTION:
The load of rotating the gear is heavy, so be careful not to get injured.
Disengage Gear
6
Troubleshooting > Other > Remedy to be implemented when the ETB Disengage Member (Transfer Frame Stopper) is left unremoved
ITB Unit
F-6-56
F-6-56
6
Troubleshooting > Other > Remedy to be implemented when the ETB Disengage Member (Transfer Frame Stopper) is left unremoved
7) Remove the Transfer Frame Stopper.
Transfer Frame Stopper
F-6-55
F-6-55
6-31
F-6-57
F-6-57
6-31