4
Parts Replacement and Clearning > Image Formation System > Removing the Hopper Unit
13) Set the Lock Lever back.
14) Remove the Hopper Unit.
•
4 Screws
•
2 Connectors
•
1 Hook
x4
4
Parts Replacement and Clearning > Image Formation System > Removing the Hopper Unit
F-4-258
x2
F-4-259
CAUTION:
When installing the Hopper Unit, be sure to follow the order as shown in the figure to
tighten screws.
x4
4-159
F-4-260
4-159