Canon imageRUNNER ADVANCE 8105 Series Service Manual page 443

Hide thumbs Also See for imageRUNNER ADVANCE 8105 Series:
Table of Contents

Advertisement

4
Parts Replacement and Clearning > Image Formation System > Removing the Pre-transfer Charging Assembly Shutter Unit
5) Remove the Motor Unit from the Pre-transfer Charging Assembly Shutter Unit.
3 Claws
x3
<Installation Method>
MEMO:
Be sure to put the protrusion of the Pre-transfer Charging Assembly Shutter Unit
between the arms.
1) Install the Pre-transfer Charging Assembly Shutter Unit.
3 Screws
x3
4
Parts Replacement and Clearning > Image Formation System > Removing the Pre-transfer Charging Assembly Shutter Unit
2) Pull the Shutter with your fingers to hook it to the Cleaner Unit.
F-4-219
CAUTION:
When installing the Motor Unit, fit the PCB into the slot.
MEMO:
Be sure to check that the rear shaft is secured.
F-4-220
4-147
F-4-221
F-4-222
4-147