4 Repair
4.5.3. Replacement of balancing device
Continued
Refitting, balancing device
The procedure below details how to refit the balancing device.
312
工控帮助教小舒QQ2823408167
Action
1.
DANGER!
Turn off all electric power, hydraulic and
pneumatic pressure supplies to the robot!
Turn off all electric power and hydraulic but not
the air pressure to the gearboxes, motors and
SMB.
2. Secure the lower arm to the frame by inserting
the locking screw into the attachment hole in
the frame.
3. Secure the bearing attachments to the
balancing device with securing screws.
4. Refit the two parallel pins in the frame.
5. Fit two guide pins to the upper holes in the
frame, where the bearing attachments are to be
attached.
6. Fit the lifting eye to the balancing device.
7.
CAUTION!
The balancing device weighs 210 kg! All lifting
equipment used must be sized accordingly!
8.
CAUTION!
The balancing device weighs 300 kg! All lifting
equipment used must be sized accordingly!
9. Lift the balancing device and bring it forward,
gliding the bearing attachments on to the guide
pins.
Note
Art. no. is specified in
Required
equipment on page
309!
Attachment hole is shown in the
figure
Attachment points, balancing
device on page
308.
Shown in the figure
Attachment
points, balancing device on page
308!
Dimension of the securing screws is
specified in
Required equipment on
page
309.
Shown in the figure
Location of
balancing device on page
307!
Art. no. is specified in
Required
equipment on page
309!
Attachments are shown in the
Attachment points, balancing device
on page
308.
NOTE!
Make sure not to burden the guide
pins with the weight of the balancing
device!
Continues on next page