3 Maintenance
3.5.4. Rust preventive measures, support bearing in wrist (Foundry Prime)
Continued
3. Dismantle the air hose from motor axis 6.
4. Tighten the hose clamp on motor axis 6, and
5. Remove the cover.
6. Apply rust preventive on the bearing and cable
7. Refit the cover.
8. Perform a leakdown test.
230
工控帮助教小舒QQ2823408167
Action
remove the air hose.
bracket with the brush.
Note
A
xx0600002864
•
A: Cover
See
Location of bearing on page
229.
See
Inspection of air hoses
(Foundry Prime) on page
191.
3HAC022033-001 Revision: K