ABB IRB 7600 Series Product Manual page 30

Hide thumbs Also See for IRB 7600 Series:
Table of Contents

Advertisement

1 Safety
1.2.2.6. Risks associated with live electric parts
Continued
Voltage related risks, IRC5 controller
A danger of high voltage is associated with, for example, the following parts:
Voltage related risks, manipulator
A danger of high voltage is associated with the manipulator in:
Voltage related risks, tools, material handling devices, etc.
Tools, material handling devices, etc., may be live even if the robot system is in the OFF
position. Power supply cables which are in motion during the working process may be
damaged.
28
工控帮助教小舒QQ2823408167
Be aware of stored electrical energy (DC link, Ultracapacitor bank unit) in the
controller.
Units such as I/O modules, can be supplied with power from an external source.
The mains supply/mains switch
The transformers
The power unit
The control power supply (230 VAC)
The rectifier unit (400-480 VAC and 700 VDC. Note: Capacitors!)
The drive unit (700 VDC)
The drive system power supply (230 VAC)
The service outlets (115/230 VAC)
The customer power supply (230 VAC)
The power supply unit for additional tools, or special power supply units for the
machining process.
The external voltage connected to the controller remains live even when the robot is
disconnected from the mains.
Additional connections.
The power supply for the motors (up to 800 VDC).
The user connections for tools or other parts of the installation (max. 230 VAC, see the
chapter Installation and commissioning in the Product manual).
3HAC022033-001 Revision: K

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents