ABB IRB 7600 Series Product Manual page 14

Hide thumbs Also See for IRB 7600 Series:
Table of Contents

Advertisement

Overview of this manual
Continued
Revision
E
F
G
12
工控帮助教小舒QQ2823408167
Description
New variant of the robot (IRB 7600 - 325/3.1) implemented throughout
the manual.
In chapter 3 Maintenance section Oil in gearboxes type of oil and art.
no. in gearbox axes 1 has been added.
New product name has been implemented throughout the manual:
"Mobilgear 600 XP 320". Replaces "Mobil Gearlube X320".
Interval for change of Shell Tivela S 150 has been changed in section
Maintenance schedule.
Section Service Information System has been removed from the
manual. There is a specific manual for SIS. See References.
Section Chip and dust protection has been removed from the manual.
This option is no longer available.
Standard tightening torque for M24 Allen head screws has been added
in section Screw joints.
Prerequisites in section Overview
This revision includes the following additions and/or changes:
Section "WARNING! - Mixed oils may cause severe damage to
gearboxes" in chapter Safety, has been integrated in section "Type of oil
in gearboxes" in the Maintenance chapter.
The oil Shell Tivela S150 in gearboxes 1, 2, 3 and 6 has been replaced
by Kyodo Yushi TMO 150. Changes made in chapters Maintenance and
Spare Parts.
The section "Type of oil in gearboxes" in chapter Maintenance has been
updated according to changes made in oil types and intervals for oil
change.
Sections "Robot transportation precaution" and "Securing the robot" are
added to the Installation chapter.
Modified maintenace intervals for oil change in gearboxes.
Chapter Maintenance, section "Mainenance Schedule": interval for
replacement of battery pack changed.
Section "Type of oil" changed.
This revision include the following addition:
New WARNING! added in Safety chapter section Work inside the
robot´s working range.
New WARNING! added in Safety chapter section WARNING! - Safety
risks during work with gearbox oil.
The text in the introduction to chapters Installation, Maintenance and
Repair has been uppdated concerning the robot being connected to
earth when power connected.
Section Expected component life in chapter Maintenance: The lifetime
of certain parts has been updated.
Section Type of oil in chapter Maintenance has been updated.
Section Foundry Plus, Cable guard added to Installation chapter.
Continues on next page