Refrigerant Recovery Procedure - Subaru Legacy 2004 Service Manual

Hide thumbs Also See for Legacy 2004:
Table of Contents

Advertisement

HVAC SYSTEM (HEATER, VENTILATOR AND A/C)
3. Refrigerant Recovery Proce-
dure
A: PROCEDURE
CAUTION:
• During operation, be sure to wear protective
goggles and protective gloves.
• Connect the refrigerant recovery system with
the manifold gauge set to discharge the refrig-
erant from the A/C system and reuse it.
• When reusing the discharged refrigerant,
keep service cans on hand. Because the dis-
charge rate with the recovery system is approx.
90%, service cans are necessary to charge the
refrigerant.
• Follow the detailed operation procedure de-
scribed in the operation manual attached to the
refrigerant recovery system.
1) Perform the compressor oil return operation.
<Ref. to AC-25, PROCEDURE, Compressor Oil.>
2) Stop the engine.
3) Make sure the valves on low-/high-pressure
sides of manifold gauge set are fully closed.
(A)
(C)
(A) Low-pressure gauge (Compound pressure
gauge)
(B) High-pressure gauge
(C) Close

Refrigerant Recovery Procedure

(B)
(C)
AC-00021
AC-20
4) Install the low-/high-pressure hoses to the ser-
vice ports on the low-/high-pressure sides of the
vehicle respectively.
(A)
(C)
(D)
(A) Low-pressure gauge (Compound pressure
gauge)
(B) High-pressure gauge
(C) Close
(D) Low-pressure side service port
(E) High-pressure side service port
5) Connect the center hose to the refrigerant recov-
ery system.
6) Follow the operation manual to activate the re-
frigerant recovery system.
(B)
(C)
(E)
AC-00022

Advertisement

Table of Contents
loading