2. Horn System
A: WIRING DIAGRAM
1. HORN
<Ref. to WI-245, WIRING DIAGRAM, Horn Sys-
tem.>
B: INSPECTION
1. HORN RELAY
Measure the horn relay resistance between termi-
nals (indicated in table below) when connecting the
terminal No. 4 to battery positive terminal and ter-
minal No. 3 to battery ground cable.
(1)
(2)
(2)
(3)
(4)
Current
Terminal No.
Flow
1 and 2
No Flow
Horn System
(1)
(3)
(4)
COM00001
Standard
Less than 1 !
More than 1 M!
COM-3