11) Carefully draw out the input shaft, and then re-
move the valve assembly.
12) Using a drill, release the caulking of holder.
CAUTION:
Make a hole approx. 2 mm (0.08 in) depth using
a drill bit of 3 mm (0.12 in) diameter.
13) Using a spanner [36 mm width across flats] or
adjustable wrench, remove the holder.
(1) Holder
14) Remove the rack bushing and rack stopper
from rack assembly.
15) Remove the oil seal from rack.
Steering Gearbox [LHD Model]
PS-00117
PS-00516
(1)
PS-00512
PS-29
POWER ASSISTED SYSTEM (POWER STEERING)
16) Insert the ST from pinion housing side, and
then remove the oil seal using a press.
ST 34099PA010 OIL SEAL REMOVER (3.0 R
model)
ST 34199AE050 OIL SEAL REMOVER (Except
for 3.0 R model)
(1) Press
(2) Oil seal
17) Using a press, remove the bushing at gearbox
installation portion.
2. CONTROL VALVE
1) Disconnect the pipes A and B from gearbox.
2) Secure the gearbox removed from the vehicle in
vise using ST.
ST1 926200000
STAND
ST2 34199AG000 BOSS D
(1)
ST
(2)
PS-00138