ST−24
Terminal 50
Terminal C
Disconnect
Terminal 30
STARTING (1GR−FE)
TEST
NOTICE:
These tests must be done within 3 to 5 seconds to avoid the
coil to be burned − out.
1.
(a)
Battery
B17617
(b)
B17619
(c)
Disconnect
B17621
(d)
Ammeter
B17623
−
STARTER (2.0 kW)
INSPECT STARTER ASSY
Do pull−in test.
(1)
Disconnect the field coil lead wire from terminal C.
(2)
Connect the battery to the magnetic switch as
shown. Check that the clutch pinion gear protrudes.
Do holding test.
(1)
Disconnect the negative (−) lead from the terminal
C with the above condition (a) is being sustained.
Check that the pinion gear remains protruded.
Inspect clutch pinion gear return.
(1)
Disconnect the negative (−) lead from the switch
body. Check that the clutch pinion gear returns in-
ward.
Perform the operation test without load.
(1)
Connect the field coil lead wire to terminal C.
Torque: 5.9 N m (60 kgf cm, 52 in. lbf)
(2)
Hold the starter with a vise.
(3)
Connect the battery and ammeter to the starter as
shown.
(4)
Check that the ammeter indicates the specified cur-
rent.
Specified current: 100 A or less at 11.5 V
ST0PX−01