ST−8
Free
Lock
Terminal 50
Terminal C
STARTING (1GR−FE)
5.
Rotate the pinion gear clockwise, and check that it turns freely.
Check that it locks by rotating the pinion gear counterclockwise.
If necessary, replace the clutch assembly.
A23160
6.
(a)
If necessary, replace the repair service starter kit.
A23161
7.
(a)
If there is no continuity, replace the repair service starter kit.
Continuity
A23162
(b)
Terminal 50
If there is no continuity, replace the repair service starter kit.
Continuity
A23163
−
STARTER (1.6 kW)
INSPECT CLUTCH PINION GEAR
INSPECT REPAIR SERVICE STARTER KIT
Check the plunger.
(1)
Push in the plunger and check that it returns quickly
to its original position.
INSPECT MAGNET STATER SWITCH
Check the pull−in coil for open circuit.
(1)
Using an ohmmeter, check that there is continuity
between terminal 50 and C.
Check whether or not the hold−in coil has an open circuit.
(1)
Using an ohmmeter, check that there is continuity
between terminal 50 and the switch body.