Water Temperature Switch - Toyota Celica Supra 1986 Service And Repair Manual

Table of Contents

Advertisement

AC·20
AIR CONDITIONING
SYSTEM-
Functional
Test and Adjustment
4.
SOLAR SENSOR
Check sensor voltage.
0.3
-
O.SV
(In Daylight)
Double Vacuum Valve (OW)
(OW
is located on heater unit)
INSPECTION OF
OW
CHECK VACUUM CIRCUIT
CONTINUITY BY
BLOWING
AIR
(a)
OFF
state
All
circuit should be closed.
(b) Apply 12 volts to the positive (
+)
terminal and
ground
te-rminal
T
1
There should be
continuity
between B and C at this
time.
(c)
Apply
12 volts to the positive
(+)
terminal and
ground
terminal T
1
There should
be
continuity
be·
tween A
and
B
at this time.
If a problem
is
found, replace
the DVV.
Water Temperature Switch
INSPECTION OF WATER TEMPERATURE
SWITCH
CHECK
WATE
R
TEMPERATURE
SWITCH OPERATION
(a)
Disconnect the 1-pole connector
from
the water
temp. switch.
lb) Check continuity
between the
water temp.
switch
and ground as
follows.
Cool.ant temp.
A
B
Leu than 30°C
(86°
F•
CONTINUITY
CONTINUITY
Fr~~
1
~0
C<
(~8"
Fl
to
50
c
122
FL
NO CONTINUITY
NO CONTINUITY
More than
50°
C
{122°
F)
NO
CONTINUITY
NO
CONTI NUI
TY
If
a problem
is
found, replace water valve.