STARTING
SYSTEM
-
Starter
ST-9
STOlM
....
,.
....
,.
6.
INSTALL
STARTING
HOUSING
(a)
Place the
starter housing on
tile
magnetic
a
w itch
and
install two
screws.
(b)
Install
two
through
bolts
.
(el
Connect
the
coil lead to
the terminal on
the magnetic
switch.
PERFORMANCE TEST OF REDUCTION TYPE
STARTER
1.
CAUTION:
TheM tests
mutt
be
performed
whhln 3
to S
seconds to .void buming
out
tile coil.
PERFORM
PULL-IN
TEST
(al
Disconnect
the field
coil
lead from
terminal
C.
(b) Connect
the
battery
to
the
magnetic
switch
as shown.
Cheek that the
plunger
moves
outward
.
If
the
plunger does
not
move,
replace
the magnetic
sw~ch.
2.
PERFORM HOLO-IN
TEST
While
connected as above with the
plunger
out,
discon·
neet the negative lead
from terminal
C.
Check
that
the
plun-
ger
remains
out.
If
the
plunger
retums
inward,
replace the
megnetie
switch.
3.
CHECK PlUNGER RETURN
Disconnect
the negative
lead
f
rom
the swit
ch
body.
Cheek
that
the plunger returns
inward.
If
the
plunger
does not
retum,
replace
the
magnetic
switch.
4
.
PERFORM NO-LOAD PERFORMANCE TEST
(al
Connect
the
battery and ammeter
to
the starter
as
shown.
(b)
Cheek
that
the starter
rotates smoothly and steadily
with
the
pinion moving
out.
Cheek
that the
ammeter
reads
the specified
current.
Specified
cu"ent:
Leoo
than 90
A
at
11
.6
V

Hide quick links: