Toyota Celica Supra 1986 Service And Repair Manual page 225

Table of Contents

Advertisement

CHARGING SYSTEM
-
Alternator
CH-7
......
"""'
5.
REMOVE REAR
END
FRAME
(a)
Remove the
four
nuts.
(b) Using
SST,
remove the
rear
end frame and four
tor·
minal insulators.
SST 09286-46011
6.
REMOVE ROTOR
FROM
DRIVE
END
FRAME
INSPECTION
OF A
LTERNATOR
Rotor
1.
CHECK ROTOR
FOR
OPEN CIRCUIT
Using an
ohmmeter,
check
lor continuity between
the slip
rings.
Standard r"'istance:
L"'s than
3
n
If
there
is
no continuity, repl- the rotor
.
2.
CHECK ROTOR FOR
GROUND
Using an
ohmmeter,
check that there
is
no continuity
be-
tween
the slip
ring and the
rotor. If
there
is continuity,
replace the
rotor.
3.
INSPECT
SLIP RINGS
(a) Check
that
the slip
rings are
not rough
or scored.
If
rough
or
scored,
replace
the
rotor.
(b)
Using
calipers, measure
the
slip
ring
diameter.
Standard
diameter:
14.4 mm (0.567 in.)
Minimum
diameter:
14.0 mm
(0.651
in.)
If
the
diameter
of
the slip
ring is
less than
the
minimum,
replace the
rotor.
Stator
1.
INSPECT
STATOR FOR OPEN
CIRCUIT
Using an
ohmmeter,
check
all leads
for
continuity.
If there
is no continuity, replace the drive
end
frame
assembly.

Hide quick links: