Sending Trap Messages When Test Failed; Sending Trap Messages When Probes Failed - Huawei Quidway S9300 Configuration Manual - Network Management

Terabit routing switch
Hide thumbs Also See for Quidway S9300:
Table of Contents

Advertisement

6 NQA Configuration
No.
1
2
3

6.33.2 Sending Trap Messages When Test Failed

A trap message is sent to the NMS when the transmission of NQA test packets fails.
Context
Do as follows on the NQA client:
Procedure
Step 1 Run:
system-view
The system view is displayed.
Step 2 Run:
nqa test-instance admin-name test-name
An NQA test instance is created and the test instance view is displayed.
Step 3 Run:
send-trap testfailure
Sending trap messages when tests fail is enabled.
By default, the trap function is disabled.
Step 4 Run:
test-failtimes times
The number of test failures that trigger sending a trap message is configured.
By default, a trap message is sent for each test failure.
----End

6.33.3 Sending Trap Messages When Probes Failed

A trap message is sent to the NMS when the NQA test fails.
Procedure
Step 1 Run:
system-view
6-126
Data
Administrator name and test name
NQA events that trigger the trap function
l (Optional) Number of test failures that trigger sending a trap message
l (Optional) Number of probe failures that trigger sending a trap message
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Quidway S9300 Terabit Routing Switch
Configuration Guide - Network Management
Issue 03 (2010-09-20)