Procedure
Step 1 Run:
system-view
The system view is displayed.
Step 2 Run:
nqa test-instance admin-name test-name
An NQA test instance is created and the test instance view is displayed.
Step 3 Run:
test-type lspjitter
The test type is set to LSP Jitter.
Step 4 Run:
lsp-type te
The tunnel type is set to be the MPLS TE tunnel.
Step 5 Run:
lsp-tetunnel tunnel tunnel-number
The TE tunnel interface to be tested is configured.
Step 6 (Optional) Perform the following as required to configure other parameters for the MPLS TE
Jitter test:
l To configure the response mode of the Echo packet, run the lsp-replymode { no-reply |
l To configure the source IP address, run the source-address ipv4 ip-address command.
l To configure the packet size, run the datasize size command.
l To configure the maximum TTL value of the packet, run the ttl number command.
l To configure the LSP EXP value, run the lsp-exp exp command.
l To configure the padding character of the packet, run the datafill fillstring command.
l To configure the interval for sending the test packets, run the interval { milliseconds
l To configure the percentage of the failed NQA tests, run the fail-percent percent command.
Step 7 Run:
start
The NQA test is started.
Select the start mode as required because the start command has several forms.
Issue 03 (2010-09-20)
udp | udp-via-vpls | udp-router-alert | level-control-channel } command.
NOTE
In a uni-directional LSP Ping test, if the lsp-replymode no-reply command is configured, the test
result displays that the test fails regardless of whether the test, actually, is successful or fails. If the test
is successful, the test result also displays the number of the timeout packets. If the test fails, the test
result displays the number of the discarded packets.
interval | seconds interval } command.
NOTE
The minimum interval for sending test packets is one second and the maximum interval is 60 seconds.
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.