Sending Trap Messages When Probes Are Complete; Sending Trap Messages When The Transmission Delay Exceeds Thresholds - Huawei Quidway S9300 Configuration Manual - Network Management

Terabit routing switch
Hide thumbs Also See for Quidway S9300:
Table of Contents

Advertisement

Quidway S9300 Terabit Routing Switch
Configuration Guide - Network Management
The system view is displayed.
Step 2 Run:
nqa test-instance admin-name test-name
An NQA test instance is created and the test instance view is displayed.
Step 3 Run:
send-trap probefailure
Sending trap messages when probes fail is enabled.
By default, the trap function is disabled.
Step 4 Run:
probe-failtimes times
The number probe failures that trigger sending a Trap message is configured.
By default, a trap message is sent for each probe failure.
----End

6.33.4 Sending Trap Messages When Probes Are Complete

A trap message is sent to the NMS when the NQA test is complete.
Context
Do as follows on the NQA client:
Procedure
Step 1 Run:
system-view
The system view is displayed.
Step 2 Run:
nqa test-instance admin-name test-name
An NQA test instance is created and the test instance view is displayed.
Step 3 Run:
send-trap testcomplete
Sending trap messages when tests are completed is enabled.
By default, the trap function is disabled.
----End
6.33.5 Sending Trap Messages When the Transmission Delay
Exceeds Thresholds
A trap message is sent to the NMS when the test result exceeds the threshold.
Context
Do as follows on the NQA client:
Issue 03 (2010-09-20)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
6 NQA Configuration
6-127