Checking The Configuration - Huawei Quidway S9300 Configuration Manual - Network Management

Terabit routing switch
Hide thumbs Also See for Quidway S9300:
Table of Contents

Advertisement

Quidway S9300 Terabit Routing Switch
Configuration Guide - Network Management
l Run:
l Run:
----End

6.30.3 Checking the Configuration

After setting universal parameters for NQA test instances, you can view the test result.
Prerequisite
The configurations of the Universal NQA Test Parameters function are complete.
Procedure
Step 1 Run the display nqa-agent [admin-name test-name ] [ verbose ] to view the status of the test
instance configured on the NQA client.
----End
Example
<Quidway> display nqa-agent
NQA Tests Max:2000
NQA Flow
nqa test-instance a a
test-type pwe3trace
local-pw-id 1
vc-type bgp
nqa status : normal
nqa test-instance a b
test-type icmpjitter
destination-address ipv4 100.1.1.201
source-address ipv4 100.1.1.200
hardware-based enable
ttl 100
tos 100
timeout 20
nqa status : normal
Issue 03 (2010-09-20)
The lifetime is set for the Trace test instance.
NOTE
This parameter can be configured only for Trace, LSP Trace, MTrace, Path Jitter and PWE3 Trace test
instances.
vpn-instance vpn-instance-name
The VPN instance name is configured for the NQA test instance.
NOTE
This parameter cannot be configured for DNS, LSP Ping, LSP Trace, LSP Jitter, PWE3 Ping, and
MTrace test instances. When the signaling protocol of the VC is BGP, this parameter can be configured
for PWE3 Trace test instances.
vc-type { ldp | bgp }
The signaling protocol type is configured for the L2VPN VC.
NOTE
This parameter can be configured only for PWE3 Ping and PWE3 Trace test instances. In the case of
the PWE3 Ping test instance, this parameter can be configured only when the signaling protocol is
LDP.