6 NQA Configuration
Select the start mode as required because the start command has several forms.
l To perform the NQA test immediately, run the start now [ end { at [ yyyy/mm/dd ]
l To perform the NQA test at the specified time, run the start at [ yyyy/mm/dd ] hh:mm:ss
l To perform the NQA test after a certain delay period, run the start delay { seconds second
----End

6.6.3 Checking the Configuration

After configuring the FTP download test, you can view the test result.
Prerequisite
The configurations of the FTP Download Test function are complete.
Context
Procedure
Step 1 Run the display nqa results [ test-instance admin-name test-name ] command to view the test
results on the NQA client.
----End
Example
Run the display nqa results command. If the test is successful, the following is displayed.
l
l
l
<Quidway> display nqa results
NQA entry(admin, ftp) :testflag is inactive ,testtype is ftp
1 . Test 1 result
6-14
hh:mm:ss | delay { seconds second | hh:mm:ss } | lifetime { seconds second | hh:mm:ss } } ]
command.
The test instance is started immediately.
[ end { at [ yyyy/mm/dd ] hh:mm:ss | delay { seconds second | hh:mm:ss } | lifetime
{ seconds second | hh:mm:ss } } ] command.
The test instance is started at a specified time.
| hh:mm:ss } [ end { at [ yyyy/mm/dd ] hh:mm:ss | delay { seconds second | hh:mm:ss } |
lifetime { seconds second | hh:mm:ss } } ] command.
The test instance is started after a certain delay.
NOTE
NQA test results cannot be displayed automatically on a terminal. You must run the display nqa results
command to view test results. By the default, the command output contains the records about only the last
five tests.
"CtrlConnTime"
"DataConnTime"
"SumTime"
The test is finished
SendProbe:1
Completion :success
MessageBodyOctetsSum: 448
Operation timeout number: 0
Drop operation number:0
CtrlConnTime Min/Max/Average: 438/438/438
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Quidway S9300 Terabit Routing Switch
Configuration Guide - Network Management
ResponseProb:1
RTD OverThresholds number: 0
Stats errors number: 0
System busy operation number:0
Disconnect operation number: 0