6 NQA Configuration

6.27.2 Configuring Parameters for the PWE3 Trace Test on a One-Hop PW

This part describes how to set PWE3 trace test parameters for a single-hop PW.
6.27.3 Checking the Configuration
After performing the PWE3 trace test for a single-hop PW, you can view the test result.

6.27.1 Establishing the Configuration Task

Before configuring a PWE3 trace test for a single-hop PW, familiarize yourself with the
applicable environment, complete the pre-configuration tasks, and obtain the required data. This
can help you complete the configuration task quickly and accurately.
Applicable Environment
To trace a one-hop PW using LDP as the signaling protocol, you can perform the PWE3 Trace
test on the one-hop PW.
Pre-configuration Tasks
Before configuring the PWE3 Trace test on a one-hop PW, you must correctly configure the
dynamic one-hop PW.
Data Preparation
To configure the PWE3 Trace test on a one-hop PW, you need the following data.
No.
1
2
3
4
5
6
6.27.2 Configuring Parameters for the PWE3 Trace Test on a One-
Hop PW
This part describes how to set PWE3 trace test parameters for a single-hop PW.
Context
Do as follows on the NQA client:
6-102
Data
ID of the PW
Type of the PW
Type and number of the interface connected with the CE
Destination IP address and ID of the L2VC
(Optional) Response mode of the Echo packets, LSP EXP, maximum hops, number
of probes, TTL value, and timeout period of the packets
Start mode and end mode of the test
Huawei Proprietary and Confidential