Configuring Parameters For The Pwe3 Trace Test On A Multi-Hop Pw - Huawei Quidway S9300 Configuration Manual - Network Management

Terabit routing switch
Hide thumbs Also See for Quidway S9300:
Table of Contents

Advertisement

6 NQA Configuration
Data Preparation
To configure the PWE3 Trace test on a multi-hop PW, you need the following data.
No.
1
2
3
4
5
6
6.28.2 Configuring Parameters for the PWE3 Trace Test on a Multi-
Hop PW
This part describes how to set a PWE3 trace test parameters for a multi-hop PW.
Context
Do as follows on the NQA client:
Procedure
Step 1 Run:
system-view
The system view is displayed.
Step 2 Run:
nqa test-instance admin-name test-name
An NQA test instance is created and the test instance view is displayed.
Step 3 Run:
test-type pwe3trace
The test type is set to PWE3 Trace.
Step 4 (Optional) Run:
vc-type ldp
The method of setting up a PW is configured.
Step 5 Run:
local-pw-type { local-pw-type | ip-interworking }
The type of the local PW is configured. By default, the type is Ethernet.
6-106
Data
ID of the local end of the PW
ID or IP address of the remote end of the PW
Type of the PW
(Optional) Response mode of the Echo packets, LSP EXP, maximum hops, number
of probes, TTL value, and timeout period of the packets
Type and number of the interface connected with the CE
Start mode and end mode of the test
Huawei Proprietary and Confidential