6 NQA Configuration
Procedure
Step 1 Run the display nqa-agent [ admin-name test-name ] [ verbose ] to view the status of the test
instance configured on the NQA client.
----End
Example
Using the display nqa-agent test-instance admin-name test-name verbose command, you can
view the uni-directional transmission delay threshold configured for the NQA test. For example:
<Quidway> display nqa-agent verbose
NQA Tests Max:2000
NQA Flow
nqa test-instance admin jitter
test-type jitter
destination-address ipv4 100.1.1.201
destination-port 80
send-trap probefailure
send-trap testfailure
send-trap testcomplete
send-trap rtd
send-trap owd-sd
send-trap owd-ds
threshold owd-sd 2000
threshold owd-ds 2000
nqa status : normal

6.33 Configuring the Trap Function

This section describes how to configure the trap function in an NQA test instance. After the trap
function is configured, a trap message is sent to the NMS in case of transmission success or
transmission failure.
6.33.1 Establishing the Configuration Task
Before configuring the trap function, familiarize yourself with the applicable environment,
complete the pre-configuration tasks, and obtain the required data. This can help you complete
the configuration task quickly and accurately.
6.33.2 Sending Trap Messages When Test Failed
A trap message is sent to the NMS when the transmission of NQA test packets fails.
6.33.3 Sending Trap Messages When Probes Failed
A trap message is sent to the NMS when the NQA test fails.
6.33.4 Sending Trap Messages When Probes Are Complete
A trap message is sent to the NMS when the NQA test is complete.
6.33.5 Sending Trap Messages When the Transmission Delay Exceeds Thresholds
A trap message is sent to the NMS when the test result exceeds the threshold.
6.33.6 Checking the Configuration
After the trap function is enabled in an NQA test instance, you can view trap messages in the
trap buffer.
6-124
NQA Tests
Max:1000
NQA Flow Remained:1000
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Quidway S9300 Terabit Routing Switch
Configuration Guide - Network Management
Number:
1
Issue 03 (2010-09-20)

Advertisement

Table of Contents
loading

Table of Contents