2. When pressing the AQS switch, the AQS indicator on display window comes on, and the air source selection is
automatically changed to recirculation mode (REC). At this moment, the self diagnosis and preheating mode of
AQS is performed for 35 seconds.
NOTICE
• When pressing DEF switch during in this process, the AQS indicator goes out and the air source selection is
changed to fresh air mode from recirculation mode.
• When pressing the AQS switch again, the self diagnosis and preheating mode of AQS operates only for the
remaining time.
3. After the self diagnosis and preheating mode of AQS is completed, the AQS system operates according to the air
pollution.
If the air pollution is not serious, the AQS system changes the air source selection to fresh air mode.
4. Although turning off the air conditioner while the AQS is in operation, the AQS stays ON (indicator on). However,
if the air conditioner is turned on by turning the ignition switch ON from OFF, the AQS stops its operation and the
indicator goes out and the display window shows the initial screen.
CHANGED BY
EFFECTIVE DATE
AFFECTED VIN
AQS indicator comes on
Changed to recirculation mode
from fresh air mode
AQS switch
NOTE
• If the AQS switch is pressed in, the AQS function
works regardless of air conditioner controller
operation.
27