SSANGYONG Kyron Repair Manual page 509

Hide thumbs Also See for Kyron:
Table of Contents

Advertisement

Cooling Start Airflow Control
When the intake temperature sensor indicates over 35°C,
the voltage value increases by 1 V/sec with delay from
3 seconds after the compressor starts its operation.
In the initial operation stage, the hot air is discharged to
the windshield (DEF mode) for a specific period of time
(approx. 5 seconds). This prevents the hot air from sud-
denly discharging to the front passengers.
Amount of Sunload Compensation Control
The air flow is directed to "VENT" according to the
amount of sunload. In "VENT" and "B/L" modes, the
blower voltage increases within 2.5 V.
DEF Mode Compensation Control
In "DEF" mode, the voltage increases 2 V compared to
that in "AUTO" mode. The voltage after compensation
should not exceed 7 V.
Maximum Cooling/Heating Control
17.5°C (Max.)
Mode
Inside air/Ambient air
Ambient air
Air mix
Air conditioner
Blower motor
CHANGED BY
EFFECTIVE DATE
AFFECTED VIN
32.5°C (Min.)
Foot
VENT
Inside air
100%
0%
OFF
ON
Hi
Hi
Ambient Air Temperature Display
When the AMB button is pressed, the ambient tempera-
ture is displayed for 5 seconds. When the vehicle stops
while driving, the ambient temperature before stop is
displayed.
Recirculation Control
A. AUTO control: Fresh air, 20% of fresh air, Recircu-
lated air
B. MANUAL control: Fresh air, Recirculated air
C. COMP OFF control: Fresh air (AUTO mode)
D. PTC linked control: When PTC is activated, the recir-
culation door is fixed at 30% of fresh air position.
When PTC is deactivated, it returns to previous mode.
E. AQS control: In initial stage, the recirculation mode is
activated for 35 seconds. After then AQS sensor con-
verts the mode between recirculation and fresh air.
High Intake Air Temperature Delay Control
When the intake temperature sensor indicates over 35°C,
the voltage value increases by 1 V/sec with delay from
3 seconds after the compressor starts its operation.
COMP Control
- Intake air temperature control: COMP OFF when the
thermo AMP temperature is below 2°C, COMP ON
when it is over 4°C.
15
6810
AIR CONDITIONING SYSTEM
KYRON SM - 2005.09