3. ALARM INTERVAL

Alarm interval and display changes according to the distance as below:
While reversing, if obstacles are within stage 1, the warning beep sounds with long intervals. If within stage 2, the
warning beep sounds with short intervals and if within stage 3, the warning beep sounds continuously.
Stage
L, C, R sensor
1
81 ~ 120 cm
2
51 ~ 80 cm
3
25 ~ 50 cm

4. TROUBLESHOOTING OF SENSOR

When the power is applied (gear selector lever is in "R" position), the sensor will be diagnosed once. If found any
failure due to open circuit to sensor or communication error, warning buzzer sounds for 3 seconds and the data on
failed sensor transmits to the instrument panel to light up the corresponding LED. If normal, the warning buzzer
sounds only for 65 ms.
1. Whenever the power is applied, the diagnosis mode is
initiated.
2. Sensor failure conditions (conditions for warning beep
due to failure)
1) Sensor failure conditions (conditions for warning beep
due to failure)
2) Open in sending circuit
3) Open in receiving circuit
4) Open in power circuit (+, -)
Warning beeps
When failed
(also when diagnosing the unit)
When normal
CHANGED BY
EFFECTIVE DATE
AFFECTED VIN
Interval (msec)
Back sonar (RH)
Back sonar (center)
5
8790
Remark
"Beep
"
"Beep -,
Beep -,
Beep -"
"Beep
"
Back sonar (LH)
PARKING AID SYSTEM