7410
Error Detection
After the motor starts to drive, if the position sensor value doesn't change for about 3 seconds during the seat sliding
or seatback reclining adjustment and for 1.6 seconds during the seat cushion height adjustment, it is determined
that the harness circuit is open or the sensor failure occurred.
If an error is detected,
The memory recall operation stops. However, the seat can be adjusted by manual switches.
The memory recall operation can be activated after the failure is corrected. This is determined when the system
detects the value changes from the position sensor. This is called the Release of automatic control stop
Relay Protection
Once the relay is turned on, it will not be turned off within 60 ms.
Specifications
1. Rated voltage: DC 12 V
2. Operating voltage: DC 9 ~ 16 V
3. Current consumption: Max. 500 mA (not including the load)
4. Operating temperature range: -30°C ~ 75°C
5. Reserve temperature range: -40°C ~ 85°C
6. Parasitic current: Max. 2 mA