SFP Slots

Protection
Circuits
Alarm
Monitoring
Alarm
Connectors
25
The number of SFP slots and types of supported transceivers are given
here:
Four SFP slots on the IE340-12GP, IE340-12GT and IE340-20GP
switches
Two SFP slots on the IE340L-18GP switch
100Base-FX transceivers (All models except the IE340L-18GP
switch.)
1000Base-SX/LX transceivers
Single-port Bi-directional (BiDi) 1000Base-LX transceivers
1000Base-ZX transceivers
1000Base-T twisted pair transceivers
Note
SFP transceivers are purchased separately.
The switches have optimized protection circuits to guard against the
following abnormal conditions:
Reverse input voltage polarity
Over- and under-voltage
Over-current
Peak-current and short-circuit
Over-temperature
The alarm facility lets you monitor the switch's environment and respond to
problems as they occur. Example of alarm events include:
Main power supply failure
Over-temperature
Port link down
Power requirements of all powered devices exceeding available
power budget
Powered devices exceeding individual port budgets
External Alarm contact input
The switches have two alarm connectors:
Alarm In connector for an external sensor, such as a motion
detector or door relay, to monitor the wiring closet or cabinet.
Alarm Out connector for an external alert device, such as a buzzer
or LED, to indicate switch alarms.