Creating a start program for the JOG operation

To perform the JOG operation, create a program. When creating a program, consider Control data requiring settings, Start
condition, and Start time chart. The following shows an example when the JOG operation is started for the axis 1. ([Cd.17]
JOG speed is set to 100.00mm/min.)
Control data requiring settings
The following control data must be set to execute the JOG operation. The setting is executed with a program.
Setting item
[Cd.16]
Inching movement amount
[Cd.17]
JOG speed
For details on the settings, refer to the following.
Page 474 [Cd.16] Inching movement amount
Page 474 [Cd.17] JOG speed
Start condition
Satisfy the following conditions to start a program. In addition, set the required conditions in the program to prevent an
operation from starting if the conditions are not satisfied.
Signal name
Interface signal
PLC READY signal
RD75 READY signal
Module access flag
Axis stop signal
Start complete signal
BUSY signal
Error detection signal
M code ON signal
External signal
Drive unit READY signal
Stop signal
Upper limit (FLS)
Lower limit (RLS)
*1 The interlock must be provided so that the buffer memory is accessed after Module access flag [X1] turns on. When no interlock is
provided, the buffer memory may be accessed while the module parameter and module extension parameter that are sent from the CPU
module are updated. If the buffer memory is accessed during the update, an unexpected value may be read or written.
5 MANUAL CONTROL
180
5.2 JOG Operation
Setting
Setting detail
value
0
Set 0.
10000
Set a value that is equal to or larger than the value in [Pr.7]
Bias speed at start and also equal to or smaller than the one
in [Pr.31] JOG speed limit value.
Signal status
ON
The CPU module is ready.
ON
RD75 READY signal
*1
ON
The RD75 buffer memory can be
accessed.
OFF
Axis stop signal is off.
OFF
Start complete signal is off.
OFF
The RD75 is not in operation.
OFF
No error has been detected.
OFF
M code ON signal is off.
ON
The drive unit is ready.
OFF
Stop signal is off.
ON
The current position is within the limit.
ON
The current position is within the limit.
Buffer memory address
Axis 1
Axis 2
Axis 3
1517
1617
1717
1518
1618
1718
1519
1619
1719
Device
Axis 1
Axis 2
Axis 3
Y0
X0
X1
Y4
Y5
Y6
X10
X11
X12
XC
XD
XE
X8
X9
XA
X4
X5
X6
Axis 4
1817
1818
1819
Axis 4
Y7
X13
XF
XB
X7