9D-66 BODY ELECTRICAL
3) If defogger is damaged by a fire between
center and negative terminal, value of voltage
is indicated 0 V.
YAD9D1H0
4) Lid of tester is moving into the section which is
assumed circuit open, after measuring circuit
open look for the section of 0 V, voltage which
is changed in the section, which is open of
circuit.
YAD9D1J0
2. After turn switch of defogger off, check the below
description.
Using voltmeter, measure resistence of each
defogger in the center of grid line, resistence
between the same terminal and defogger orderly.
Broken section of defogger is 2 times rather than
other the section of defogger, section which is
impacted with the rapid change of resistence.
YAD9D1K0
Method to repair grid line of defogger
After being prepared, repair section of defogger which
is broken.
1) Paint of applying electric current
2) Thinner of paint
3) Masking tape
4) Alcohol
YAD9D1L0