SSANGYONG Rexton Y200 Manual page 1593

Hide thumbs Also See for Rexton Y200:
Table of Contents

Advertisement

SSANGYONG Y200
Check motor of power window
After terminal of motor is connected, check that motor
is operating softly, and then change pole of current,
motor is operating to the reverse direction softly, if
motor is operating unnormal, and then replace motor.
YAD9D1D0
Check rear window and defogger of quarter glass
Notice: It is prevention for the defogger not to have a
impact, so after taping foil of tin at the end of tester,
foil of tin is moving along with line of grid for checking
the circuit open or not.
YAD9D1E0
1. At the state of idling, after switch of defogger is
turned on, check the below description.
1) After turn switch of defogger on, measure
voltage of defogger with voltmeter in the center
of glass, if value of voltage is 6V, heater line of
rear window is normal.
YAD9D1F0
2) If defogger is damaged by a fire between
center and positive terminal, value of voltage
is indicated 12 V.
YAD9D1G0
BODY ELECTRICAL 9D-65