1. SPECIFICATIONS OF RK - STICS

1) Electrical Performance

Item
Rated voltage
Operating voltage
Operating temperature
Reserved temperature
Max. operating humidity
Resistible voltage
Insulating resistance
Parasitic current
Voltage drop
2) Chattering of Input Signals
1.
Vehicle speed input:
The vehicle speed calculating time is 1.0 seconds. The elapsed time of 1.5 seconds after IGN
1 switch :ON" is not included.
2.
20 ms target input:
Wiper motor A/S (parking) terminal
3.
100 ms target input switch
All switches except wiper motor A/S (parking) terminal
3) Time Tolerance
If not indicated, time tolerance will be ± 10%.
1.
However, if less than 500 ms, time tolerance will be ± 50 ms.
2.
The time indicated in each function does not include chattering processing time from switch
input changing point.
Requirement
DC 12V
DC 9 ~ 16V
-30℃ ~ +80℃
-40℃ ~ +85℃
95%
24V
No heat and fire due
to the current leaks.
below 4.0mA
(below 6.0mA)
below 1.2 V
below 2.0 V
Remark
Should operate normally within this range.
Confined with PCB, waterproof and coating
that requires the insulation.
IGN = OFF, Full output load = OFF, 90
seconds (after received the signals), No input
changes for 2 seconds
Pin no. 8 and 2, 3, 5, 7, 10, 12, 13, 15, 19,
20, 23, 40, 47, 51, 53, 54
Pin no. 8 and 1, 14
02-3