Service Name Set Prot - Siemens SCALANCE S615 Configuration Manual

Simatic net industrial ethernet security command line interface
Hide thumbs Also See for SCALANCE S615:
Table of Contents

Advertisement

Security and authentication
9.2 Firewall
Result
The corresponding service is deleted.
Further notes
You display the available service names with the
You create a service with the
You display this setting and other information with the
command.
9.2.4.39

service name set prot

Description
With this command, you change the protocol.
Requirement
● The service name has been created.
● You are in the FIREWALL configuration mode.
The command prompt is as follows:
cli(config-fw)#
Syntax
Call up the command with the following parameters:
service name <string(32)> set proto {udp|tcp}
The parameters have the following meaning:
Parameter
string
UDP
TCP
Result
The protocol of the relevant service has been changed.
350
command.
service name
Description
Service name
The service is valid only for UDP
frames.
The service is valid only for TCP
frames.
command.
service show-names
show firewall ip-services
Range of values / note
Specify a valid service name.
Maximum of 32 characters
-
-