Configuration
2.1 System
2.1.10.10

shutdown complete

Description
With this command, you shut down the interface.
Requirement
You are in the Interface Configuration mode.
The command prompt is as follows:
cli(config-if-$$$)#
Syntax
Call the command without parameters:
shutdown complete
Result
The Interface is shut down.
Note
If you use this command in the Interface Configuration mode for a VLAN (input prompt
CLI(config-if-vlan-$)#
relates to configuration using CLI, WBM and SNMP. Access is only possible again after
resetting the device to the factory settings with the Reset button.
Further notes
You activate the interface with the
You can display the status of this function and other information with the
interfaces
66
, management access to the device is no longer possible. This
command.
command.
no shutdown
Configuration Manual, 06/2015, C79000-G8976-C406-02
show