Siemens SCALANCE S615 Configuration Manual page 244

Simatic net industrial ethernet security command line interface
Hide thumbs Also See for SCALANCE S615:
Table of Contents

Advertisement

Network protocols
6.6 SNMP
Syntax
Call up the command with the following parameters:
snmp targetparams <ParamName>
user <UserName>
security-model {v1|v2c|v3{auth|noauth|priv}}
message-processing {v1|v2c|v3}[{volatile|nonvolatile}]
The parameters have the following meaning:
Parameter
ParamName
user
UserName
security-model
message-processing
Keywords need to be specified.
If optional parameters are not specified when configuring, the default values apply.
Result
The SNMP target parameters are configured.
244
Description
Name of the SNMP parameter
Keyword for the user name
Value for the user name
Specifies which SNMP version is used.
With SNMPv3 a security level (authen-
tication, encryption) can also be con-
figured.
Specifies which SNMP version is used
for processing the messages and
whether the settings remain following a
restart.
Range of values / note
max. 32 characters
-
max. 32 characters
SNMP version
v1
v2c
v3
Security level for v3
auth
Authentication enabled /
no encryption enabled
noauth
No authentication enabled,
no encryption enabled
priv
Authentication enabled /
encryption enabled
SNMP version
v1
v2c
v3
Settings after the restart
volatile
The settings are lost after
a restart
nonvolatile
volatile):
The settings are retained
after a restart
SCALANCE S615 Command Line Interface
Configuration Manual, 06/2015, C79000-G8976-C406-02
(volatile):
(non-

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents