Network protocols
6.4 DHCP server
Syntax
Call up the command with the following parameters:
lease-time <seconds (60-31536000)>
The parameter has the following meaning:
Parameter
seconds
Result
The time is configured.
Further notes
You display the setting with the
6.4.3.2

network

Description
With this command you configure the IPv4 address band from which the DHCP client
receives any IPv4 address.
Note
Maximum number of IP addresses
The maximum number of IPv4 addresses that the DHCP server supports is 100. In other
words, a total of 100 IPv4 addresses (dynamic + static).
With the static assignments, you can create a maximum of 20 entries.
Assignment of IP addresses
The requirement for the assignment is that the IPv4 address of the interface is located within
the IPv4 address band. If this is not the case, the interface does not assign any IPv4
addresses
Requirement
You are in the DHCPPOOL configuration mode.
The command prompt is as follows:
cli(config-dhcp-pool-<ID>)#
198
Description
Time until renewal of the assigned
IPv4 address in seconds
show ip dhcp-server pools
Range of values / note
60 ... 31536000
command.