Load control

This part contains the sections describing the functions for controlling and balancing network
load.
7.1

Flow control

The flow control function monitors the incoming data traffic of a port. If there is overload
("Congestion", "Overflow") it sends a signal to the connection partner. If the flow control
function receives a signal at the sending end, it stops the data transmission to avoid loss of
data.
This section describes commands of the flow control function.
7.1.1

show flow-control

Description
This command shows the settings of the flow control function.
Requirement
You are in the User EXEC mode or in the Privileged EXEC mode.
The command prompt is as follows:
cli>
Syntax
Call up the command with the following parameters:
show flow-control [interface <interface-type><interface-id>]
The parameters have the following meaning:
Parameter
interface
interface-type
interface-id
For information on names of addresses and interfaces, refer to the section "Interface
identifiers and addresses (Page 25)".
SCALANCE S615 Command Line Interface
Configuration Manual, 06/2015, C79000-G8976-C406-02
or
cli#
Description
Keyword for a an interface description
Type or speed of the interface
Module no. and port no. of the interface
Range of values / note
-
Enter a valid interface.