Sntp Unicast-Server Ipv4 - Siemens SCALANCE S615 Configuration Manual

Simatic net industrial ethernet security command line interface
Hide thumbs Also See for SCALANCE S615:
Table of Contents

Advertisement

Further notes
You can display the settings of this function and other information with the
status
4.3.6.2

sntp unicast-server ipv4

Description
With this command, you configure an SNTP unicast server.
Requirement
● The addressing mode of the SNTP client is configured as "unicast".
You are in the SNTP Configuration mode.
The command prompt is as follows:
cli(config-sntp)#
Syntax
Call up the command with the following parameters:
sntp unicast-server ipv4 <ucast_addr>[port<1025-36564>][poll<seconds(16-16284)>]
The parameter has the following meaning:
Parameter
ucast_addr
port
poll
seconds
For information on names of addresses and interfaces, refer to the section "Interface
identifiers and addresses (Page 25)".
Result
The SNTP unicast server is configured.
Further notes
You can reset the setting to the default with the
You display this setting and other information with the
command.
SCALANCE S615 Command Line Interface
Configuration Manual, 06/2015, C79000-G8976-C406-02
command.
Description
Value for an IPv4 unicast address
UDP port of the time server
Keyword for the time after which the time of day is
requested again
Value for the time in seconds
Range of values / note
Enter a valid IPv4 unicast
address
1025 ... 36564
Default: 123
-
16...16284
no sntp unicast-server ipv4
show sntp unicast–mode status
System time
4.3 SNTP client
show sntp
command.
135